Solution

Description

———— Product Features ————

  • This product series is an industrial-grade offering designed to meet industrial‑grade standards.
  • It adopts a plug-and-play modular design.
  • Based on the U.S.-originated LDC inverter magnetic parallel‑connection patent technology, it enables unlimited‑unit parallel redundancy operation.
  • Selecting a configured power equipment lifecycle management system enables fault detection, automated fault remediation, and lifespan prediction for the equipment.
  • This product series comprises two models: three-input single-output and three-input three-output.
  • The maximum capacity of a standalone system can reach 2.5 MVA.

———— Application Industries ————

It is primarily used in distributed‑power supply applications on production lines, as well as in centralized power‑supply systems such as DCS control systems, communication systems, monitoring systems, and network management centers—critical equipment and environments that require highly reliable, uninterrupted power.

Coal chemical industry

Oil & Gas (Onshore, Offshore Platforms, Pipelines, Refining, Floating Production Storage and Offloading)

Petrochemicals (onshore, offshore platforms, pipelines, refining, floating production storage and offloading)

Nuclear power, concentrated solar power, hydrogen energy, and other new energy sources

New materials, semiconductors, and other strategic emerging industries

Other industrial applications

———— Performance Features ————

It is primarily used in distributed‑power supply applications on production lines, as well as in centralized power‑supply systems such as DCS control systems, communication systems, monitoring systems, and network management centers—critical equipment and environments that require highly reliable, uninterrupted power.

01.

Fully modular design

“Plug-and-play” modular design integrates the rectifier unit, inverter unit, and isolation diodes into a single module, enabling easy plugging and unplugging and significantly reducing maintenance time.

02.

Fully redundant design

Multiple “plug-and‑play” power modules operate in parallel, achieving N+1 redundancy. The control power supply, the microprocessor on the main control board, and the cooling fans all feature dual redundant designs, ensuring that a single thermal or electrical failure will not compromise system operation. Output voltage regulation employs a 1+1 redundant closed-loop control scheme, guaranteeing that even if one feedback path fails, no high‑voltage output will be generated to damage the load.

03.

Multi-language LCD display (Chinese, English, Russian, Spanish)

Large-screen LCD display, UPS monitoring software with multi-language support, simple and intuitive operation, no language barriers, and easy to learn.

04.

Fully digital control

Employing control switching components such as DSPs and IGBTs: ensures system stability and enhances mechanical efficiency.

05.

Intelligent Parallel Hot Backup

No paralleling board is required; a single communication cable suffices to enable multiple hosts to operate in parallel with redundancy. The communication cables between the parallel hosts are arranged in a ring topology, forming a closed loop—so even if one cable is severed, it does not disrupt multi‑stage parallel operation.

06.

Human-centered control design

There are no rigid procedural restrictions; operation is straightforward, unlike other brands of UPS that impose strict operating‑procedure constraints.

07.

Unique voltage regulation method

In a three-phase inverter system composed of three independent single-phase inverters, independent voltage regulation for each phase allows for 100% unbalanced three-phase loading.

08.

Intelligent detection and speed control of the cooling fan

Any fan malfunction can be monitored via the EPS panel or through the RS‑232 interface. The fan speed automatically adjusts according to the load, extending the fan’s service life and reducing noise.

 

09.

The static switch has an extremely short switching time, enabling seamless, disturbance-free switching.

Employing 32-bit DSP digital control technology and a current‑mode detection scheme, the switching time is reduced to 0.

10.

Data recording capability

All data and timestamps associated with abnormal conditions are stored in the UPS, enabling users to clearly monitor any issues that arise. Even in the event of a power outage, the data retained in the UPS remains intact.

11.

Remote Diagnosis and Testing

Remote diagnostics and testing of multiple UPS systems are available via the Internet, ensuring your system operates at peak reliability at all times.

12.

Intelligent Communication Interface

One RS‑232 port, four RS‑485 ports, and standard communication protocols comprise the intelligent monitoring system. It also supports SNMP devices for remote network management. More than 20 pairs of passive dry contacts are available for flexible configuration and use.

———— Product Principle Block Diagram ————

EPS three-phase input single-phase output schematic diagram

EPS three-phase input and three-phase output schematic diagram

———— Product Specification Sheet ————

 

Model number DEP Series
Input Mains voltage AC 187–242 V / AC 310–450 V
Mains frequency 50Hz±10%
Input current The maximum input current is 1.2 times the rated input current.
Dual-path automatic transfer Optional
Static switch Optional
Charger Bridge rectifier Three-phase 6-pulse controlled rectifier
Circuit Architecture and Control Strategy Closed-loop control of the DC output voltage (PID), with current‑limiting negative feedback regulation for both the rectifier output current and the battery charging current.
Rated Input Voltage (VAC) 380V/400V/415V -25% to +25%, three-phase three-wire or three-phase four-wire
Input frequency 50/60Hz±10%
Charging voltage Can be set according to battery capacity.
Charging current Can be set according to battery capacity.
Battery Maintenance-free sealed battery
Battery voltage 110VDC/220VDC/360VDC
Standby time 30 minutes (configurable upon user request)
Normal state output Output voltage Consistent with the mains power supply
Output frequency Consistent with the mains power supply
Efficiency ≧99%
Emergency Status Output Output voltage Single-phase 220 V ±1%, three-phase 380 V ±1%
Output frequency 50/60Hz±0.1Hz
Rated output power factor 0.8
100% load voltage regulation ± 1 %
Total Harmonic Distortion of Voltage (at rated load) < 3 %
Dynamic Voltage Transient and Recovery Time 0–5 ms: dynamic voltage transient ≤ ±30%; 5–20 ms: dynamic voltage transient reduced to ≤ ±14%; 20–100 ms: dynamic voltage transient further reduced to ≤ ±5%. (According to GB 7260.3—5.3.1, the first‑class dynamic performance is 20–100 ms, with the dynamic voltage transient reduced to ≤ ±10% as specified in GB 7260.3—6.3.7.)
Efficiency 〉95% (at rated load)
Number of output branches 4 channels (expandable upon user request)
Output shunt characteristics Continuous type, non-continuous type, fire‑fighting linkage type
Overload characteristics Output is normal at 120%; at 150%, it lasts ≥30 seconds.
Conversion time Switching from grid power to emergency power supply takes 0 milliseconds.
The transition from emergency power supply to grid power is 0 milliseconds.
Display LED+LCD
Operating ambient temperature -30℃~+55℃
Relative humidity 0~90%
Altitude ≤2,500 m; at altitudes between 2,500 and 5,000 m, an additional system ventilation device shall be installed or derating shall be applied.
Load adaptation Various lighting loads or other capacitive and inductive motor loads
Noise When mains power is available, the system operates silently with no noise; during emergency power supply, noise levels remain below 60 dB.
Dimensions/Weight See the size/weight chart.
Door opening method Host cabinet: front door; Battery cabinet: front and rear doors
Inlet and outlet wiring method Bottom entry/exit wiring (standard type) as per customer requirements.

Related products