Solution

MPR Series Modular Redundant UPS for Power Transmission and Distribution


Related products

Description

———— Product Features ————

  • This product series is an industrial-grade offering designed to meet industrial‑grade standards.
  • It adopts a plug-and-play modular design.
  • Based on LDC’s proprietary inverter magnetic parallel‑connection patent technology, unlimited‑unit parallel redundancy operation has been achieved.
  • Selecting a configured power equipment lifecycle management system enables fault detection, automated fault remediation, and lifespan prediction for the equipment.
  • This product series comprises only three‑phase input, single‑phase output models.
  • A standalone system can be configured to achieve virtually unlimited capacity,
  • Single-phase UPS power module capacities: 2, 3, 5, 6, 7.5, and 10 kVA at 220 V DC; or 1.5, 2, 3, 4, and 5 kVA at 110 V DC.

———— Application Industries ————

Smart Substation for Nuclear Power Plants

Smart Substation for Oil & Gas

Petrochemical Smart Substation

Intelligent Substation for the Coal Chemical Industry

Smart Substation for the Chemical Industry

Other industrial applications

———— Advantages of the MPR Module ————

Professional design tailored to China’s power grid environment.

 

 

Input-output dual-isolation transformer design, input,

DC, with complete electrical isolation among the three output terminals, over-

Extremely high carrying capacity and strong anti-interference capability.

Designed and manufactured to industrial-grade standards, significantly enhancing…

of the system’s reliability

 

Two-stage phase-locked loop with automatic tracking and complete generator synchronization

Compatible

 

 

Special five-stage overload protection, better suited for various types.

of the load

 

 

Comprehensive protection features: overload, overtemperature, and output.

Short circuit, low battery voltage, high battery voltage, module

All can automatically log out and disconnect from the system.

International standard communication protocols and interfaces: MODBUS and

RS485

 

———— Technical Specifications ————

Each module has a capacity of 2, 3, 5, 6, 7.5, or 10 kVA (DC 220 V), and 1.5, 2, 3, or 4,

5 kVA (DC 220 V) can be directly and infinitely paralleled.

DC input voltage for each module: 96, 110,

192, 220V, or customized per customer requirements

 

The system can accept two distinct AC power inputs:

Working power supply, bypass power supply

 

It can operate in N+1 redundancy mode or in capacity‑expansion mode.

 

 

 

Provides an RS232 interface and includes open communication protocols.

Protocol and monitoring software. An RS485 interface is available as an option,

Standard protocols, such as MODBUS, are available.

 

 

Inverter fault, bypass fault, battery fault, utility power

Abnormality, overload, comprehensive fault, utility mode, direct

Flow mode, bypass mode; other contacts can also be selected.

Type

Provides a large-screen LCD with Chinese-language display.

———— Performance Features ————

01.

Modularization

Using 1.5–6 kVA power modules as a single unit, they can be directly and infinitely paralleled.

02.

Flexibility

The UPS capacity can be flexibly increased or decreased as needed.

 

 

 

 

03.

Redundancy

N+X redundancy can be implemented as needed to maximize system reliability.

04.

Hot-swappable backup feature

In any situation, you can easily replace modules without shutting down the UPS—providing uninterrupted protection for your equipment even during battery operation, maintenance, or capacity upgrades.

05.

Reliability

Any single point of failure will not affect the operation of the entire system.

06.

Capacity expansion issue

It can be flexibly scaled to meet users’ actual needs.

07.

Maintainability issues

Users can perform repairs themselves, without the need for professional technicians.

———— Product Principle Block Diagram ————

Principle of Non-Rechargeable Systems

Schematic Diagram of the Charging System

———— Product Specification Sheet ————

Rated output power 2~3 kVA 4~6 kVA 7~10 kVA
Output power factor 0.8
Technology Type Online double-conversion
Design Technology Input and output isolation transformer design, multi-CPU redundancy design
Structure Modular and parallelizable
Parallel Operation Settings Shared load, redundant parallel operation technology
Redundancy n+1 The standard number of parallel units is eight; the number of paralleled units can be increased upon customer request.
Capacity expansion Increase according to user electricity demand
Double-conversion AC-to-AC efficiency 85%
Noise at 100% load 50dBA
UPS ambient temperature -30~+40℃
Storage temperature -30~+70℃
Heat dissipation Forced air cooling, fan-based heat dissipation
Relative temperature <95% (non-condensing)
Standard EN 50091, Parts 1, 2, and 3
Maintenance Perform maintenance work from the front side.
Positioning At least 10 cm of clearance must be left at the rear.
Input/output cable Terminal block connection, bottom wire entry
Dry contact Multiple dry contacts are available for automation use.
Smart Interface For network management and monitoring
UPS module weight 50kg 90kg 110~150kg
UPS power module dimensions 483 x 178 x 530 mm (4U, including tray height) 483 x 356 x 530 mm (8U, including tray height) 483x534x530mm (12U including tray height)
583 x 178 x 430 mm (4U height including tray) 583 x 356 x 430 mm (8U, including tray height) 583x534x430mm (12U including tray height)

 

  ———— Rectifier Parameters ————

Input voltage Single-phase 220 V / 230 V / 240 V, three-phase 380 V / 400 V / 415 V
Input voltage range +/-25V(%)
Input frequency 45-55HZ
Input power factor 0.85
Impulse current Subject to software launch restrictions

 

  ———— Inverter Parameters ————

Rated output power 2~3 kVA 4~6 kVA 7~10 kVA
Rated output voltage Single-phase 220V/230V/240V
Output power factor 0.8

 

  ———— Output voltage range ————

Static +/-1%
- Load step change (0–100%, 100–0%) +/-5%
-Linear load distortion factor +/-2%
- Nonlinear load distortion factor ±3% (compliant with EN 50091-1)
Recovery time after a load step change (0–100%, 100–0%) 20msec
Output waveform Sine wave
Output frequency 50 or 60 Hz

 

  ———— Output frequency range ————

Free operation +/-0.1%Hz
When synchronized with the utility grid (adjustable) +/-5%Hz
Overload capacity 125 for 10 minutes, 150 for 1 minute
Peak factor 3:1 (customizable to a crest factor greater than 3:1)

 

  ———— DC parameters ————

Battery voltage 96/110/192/220VDC
Voltage range +/-20%

 

   ———— Configure cabinet specifications ————

Standard cabinet MPRC168 MPRC186 MPRC268 MPRC286 MPRC386 MPRC386
Rack configuration allowed Six 4U or three 8U power modules 3 × 8U or 6 × 4U power modules 4 × 8U or 8 × 4U power modules
1 set of manual bypass switch 1 set of manual bypass switch 1 set of manual bypass switch
1 set of standard 8-channel AC outputs 1 set of standard 8-channel AC outputs No AC distribution output
Standard cabinet configuration Cabinet body, input isolation transformer (optional), terminal block, modular plug-in terminals, cooling fan, and other components.
Maximum power rating 18KVA/14.4KW 18KVA/14.4KW 24KVA/19.2KW
Dimensions (mm): Width x Height x Depth 600x1800x800 600x2000x800 800x2000x600 600x2260x800 800x2260x600
Weight (kg) 100 120 140

Related products

No content information is currently displayed.