Solution
Description
———— Product Features ————

- This product series is an industrial-grade offering designed to meet industrial‑grade standards.
- It adopts a plug-and-play modular design.
- Based on LDC’s proprietary inverter magnetic parallel‑connection patent technology, unlimited‑unit parallel redundancy operation has been achieved.
- Selecting a configured power equipment lifecycle management system enables fault detection, automated fault remediation, and lifespan prediction for the equipment.
- This product series comprises only three‑phase input, single‑phase output models.
- The maximum capacity of a standalone system can reach 200 kVA.
- The touchscreen design provides more comprehensive information display than the NMP series host, with a greater number of hardwired signals sent to the backend and richer data on voltage, current, and other parameters received by the backend.
———— Application Industries ————

Nuclear power plant

Coal-fired power plant

Fossil-fuel power plant

Gas-fired power plant

Hydroelectric power plant

Coal chemical industry

Chemical industry

Description of UPS for Other Industrial Applications
———— Technical Specifications ————

7-inch touchscreen display, with simple, intuitive, and convenient operation.
Equipped with a power equipment lifecycle management system.

Voltage, current, and other information can be transmitted to the backend via communication.
Taiwan

Information on the touchscreen can be operated manually.

32-bit DSP all-digital control technology

Input power factor as high as 0.90

Multi-unit infinitely parallel redundant system

Extremely high overall machine efficiency

Input current distortion below 7%

International Standard Communication Protocol
———— Performance Features ————
01.
All-in-one design
The input and output isolation transformers, DC isolation diodes, manual bypass, and automatic bypass are all integrated within the UPS unit. No external components or additional configuration are required.
02.
Fully redundant design
The rectifier, inverter, static bypass, and other key components, along with their control power supplies, microprocessors on the main control board, and cooling fans, all operate in a dual-redundant configuration, ensuring that any single-point failure will not affect the overall system operation.
03.
Full Chinese character display (supports multiple languages)
Large-screen LCD display and fully Chinese-language UPS monitoring software ensure simple, intuitive operation. This eliminates language barriers for administrators, allowing them to master the system quickly.
04.
Fully modular design
“Plug-and-play” modular design ensures easy, fast maintenance and repairs, significantly reducing service time.
05.
Fully digital with hardware-compatible control
Utilizing a 32-bit DSP and IGBT-based control and switching components: effectively enhances system stability and improves efficiency.
06.
Human-centered control design
There are no rigid procedural restrictions; operation is straightforward, unlike other brands of UPS that impose strict operating‑procedure constraints.
07.
Ultra-wide input voltage range
Under full-load conditions, the input voltage range is exceptionally wide—300 VAC to 520 VAC—and even when most UPS systems rely on battery discharge to maintain stable output voltage, these units can still operate as usual.
08.
Intelligent detection and speed control of cooling fans
Any fan malfunction can be monitored via the UPS panel or through the RS‑232 interface. The fan speed automatically adjusts according to the load, extending the fan’s service life and reducing noise.
———— Product Principle Block Diagram ———— 
———— Product Specification Sheet ————
| Model (Capacity kVA) | SMP (5K 10K 15K 20K 30K 40K 50K) | SMP (60K 80K) | |||
| UPS Type | Double isolation, double conversion online type | ||||
| Efficiency | >93% | ||||
| UPS ambient temperature | -30~40℃ (+55℃, 16-hour full-load operation) | ||||
| UPS storage temperature | -30~+70℃ | ||||
| Relative humidity | <95% (non-condensing) | ||||
| Height | <1500m (above sea level) | ||||
| Power derating at altitudes above 1500 m. | 7%/km | ||||
| Ventilation method | 1+1 redundant fans, forced air cooling, top-and-bottom airflow | ||||
| Noise | <60dBA | ||||
| Input/Output Cable Connection | Bottom or top | ||||
| Communication interface | RS232 (1 port) / RS485 (1 port) / Dry contacts (1 set), SSMP optional | ||||
| Standard | CE, EN 50091-1,2 | Compliant with | |||
| FCC CLASS A | Compliant with | ||||
| Protection circuit | Short-circuit protection | Rectifier/Backup Power Supply/Bypass Switch | |||
| Lightning Protection | MOV | ||||
| EMC filtering | Input & Output | ||||
| Quarantine | Full input/output isolation | ||||
———— Rectifier ————
| Bridge Rectifier | Three-phase 6-pulse controlled rectifier | Three-phase 12-pulse controlled rectifier | |||
| Rated Input Voltage (VAC) | 380V-25%+30%, three-phase three-wire or three-phase four-wire | ||||
| Input frequency | 50/60Hz±10% | ||||
| Input power factor | >0.75 | >0.85 | |||
| DC output voltage | 110VDC/220VDC | ||||
| DC output voltage accuracy (with load varying from 0% to 100%) | ±1% | ||||
| Efficiency | >0.85 | >0.9 | |||
———— Inverter ————
| Bridge inverter | IGBT inverter with DSP control IGBT | ||||
| DC input range | 110VDC/220VDC±25% | ||||
| Rated output voltage | 110V/220/230VAC, 2P2W or 120V/240VAC, 2P2W | ||||
| Output power factor | 0.8 | ||||
| Output frequency | 50/60Hz±0.1% | ||||
| Output voltage stability | Static | ±1% | |||
| Dynamic (0~100%~0) | ±5% | ||||
| Output voltage recovery time | After a step load, it recovers to within 2% within 10 milliseconds. | ||||
| Overload capacity | 125% for 10 minutes, 150% for 1 minute. | ||||
| Short-circuit characteristics | Short-circuit protection, current limiting at 3 times the rated current, 100 ms. | ||||
| Output waveform | Sine wave | ||||
| Output waveform distortion | Linear load | <1% | |||
| Nonlinear load (crest factor 3:1) | <2% | ||||
| Peak factor | 3:1 (customizable to a crest factor greater than 3:1) | ||||
| Efficiency | >94% | ||||
| DC cold start | Okay. | ||||
———— Bypass ————
| Automatic Static Switch | Thyristor SCR | ||||
| Rated voltage | 110V/220V/230V ±20% (adjustable) or 120V/240V ±20% (adjustable) | ||||
| Rated frequency | 50/60 Hz ±5% (adjustable) | ||||
| Static bypass transfer time | <0.4ms | ||||
| Inverter to Static Bypass | Inverter testing, inverter fault, excessive inverter input voltage, excessive inverter output voltage. | ||||
| Overload capacity | 100%~110% | Long-term operation | |||
| >110%~125% | 10min | ||||
| >125%~150% | 1min | ||||
| >150% | 100mS | ||||
———— Mechanical Parameters ————
| Model number | SMP (5K 10K 15K 20K 30K) | SMP (40K 50K) | SMP (60K 80K) | ||
| Protection rating | IP20, IP21, IP30, IP32, IP40, and IP42 are available; other options can be customized. | ||||
| Cabinet dimensions | W | 600 | 800 | 1200 | |
| D | 800 | ||||
| H1 | 1800 (IP20, IP30, IP40) | ||||
| H2 | 2000(IP21, IP32, IP42) | ||||
| Weight (kg) | 700~800 | 800~1000 | 1100~2000 | ||
Related products