Solution
Description
———— Product Features ————

- This product series is an industrial-grade offering designed to meet industrial‑grade standards.
- It adopts a plug-and-play modular design.
- Based on the U.S.-originated LDC inverter magnetic parallel‑connection patent technology, it enables unlimited‑unit parallel redundancy operation.
- Selecting a configured power equipment lifecycle management system enables fault detection, automated fault remediation, and lifespan prediction for the equipment.
- This product series comprises two models: three-input single-output and three-input three-output.
- The maximum capacity of a standalone system can reach 2.5 MVA.
- Single-phase UPS power module capacities: 10 kVA, 20 kVA, 30 kVA, 40 kVA, 60 kVA, 100 kVA, 125 kVA, 200 kVA, 250 kVA.
- Three-phase UPS power module capacities: 10 kVA, 20 kVA, 30 kVA, 40 kVA, 60 kVA, 100 kVA, 125 kVA, 200 kVA, and 250 kVA.
———— Application Industries ————
It is primarily used in distributed‑power supply applications on production lines, as well as in centralized power‑supply systems such as DCS control systems, communication systems, monitoring systems, and network management centers—critical equipment and environments that require highly reliable, uninterrupted power.

Coal chemical industry

Oil & Gas (onshore, offshore platforms, pipelines, refining, floating production storage and offloading)

Petrochemicals (onshore, offshore platforms, pipelines, refining, floating production storage and offloading)

Nuclear power, concentrated solar power, hydrogen energy, and other new energy sources

New materials, semiconductors, and other strategic emerging industries

Other industrial applications
———— Technical Specifications ————
It is primarily used in distributed‑power supply applications on production lines, as well as in centralized power‑supply systems such as DCS control systems, communication systems, monitoring systems, and network management centers—critical equipment and environments that require highly reliable, uninterrupted power.

The rectifier employs 12-pulse, 18-pulse, or 24-pulse SCR rectification, while the inverter utilizes IGBT-based inversion.

32-bit DSP all-digital control technology

Parameter control and settings can be configured via software.

ABM fast-charging design, configurable via the control panel.

Input power factor as high as 0.90

Multi-unit infinitely parallel redundant system

Extremely high overall machine efficiency

Input current distortion below 7%

International Standard Communication Protocol
———— Performance Features ————
It is primarily used in distributed‑power supply applications on production lines, as well as in centralized power‑supply systems such as DCS control systems, communication systems, monitoring systems, and network management centers—critical equipment and environments that require highly reliable, uninterrupted power.
01.
Fully modular design
“Plug-and‑play” modular design (available in SDP and MDP series): the rectifier unit, inverter unit, and isolation diodes are integrated into a single module, enabling easy plug‑and‑play replacement and significantly reducing maintenance time.
02.
Fully redundant design
Multiple power modules operate in parallel, achieving N+1 redundancy. The control power supply, the microprocessor on the main control board, and the cooling fans all employ a dual-redundant design, ensuring that a single thermal or electrical failure will not compromise system operation. Output voltage regulation utilizes a 1+1 redundant closed-loop control scheme, guaranteeing that even if one feedback path fails, no overvoltage will be generated to damage the load.
03.
Multi-language LCD display (Chinese, English, Russian, Spanish)
Large-screen LCD display, UPS monitoring software with multi-language support, simple and intuitive operation, no language barriers, and easy to learn.
04.
Fully digital control
Employing control switching components such as DSPs and IGBTs: ensures system stability and enhances mechanical efficiency.
05.
Intelligent Parallel Hot Backup
No paralleling board is required; a single communication cable suffices to enable multiple hosts to operate in parallel with redundancy. The communication cables between the parallel hosts are arranged in a ring topology, forming a closed loop—so even if one cable is severed, it does not disrupt multi‑stage parallel operation.
06.
Human-centered control design
There are no rigid procedural restrictions; operation is straightforward, unlike other brands of UPS that impose strict operating‑procedure constraints.
07.
Ultra-wide input voltage range
Under full-load conditions, the input voltage range is exceptionally wide—300 VAC to 520 VAC. Even when most UPS systems rely on battery discharge to maintain stable output voltage, these units can still operate as usual.
08.
Intelligent detection and speed control of cooling fans
Any fan malfunction can be monitored on the UPS panel or via the RS‑232 interface. The fan speed automatically adjusts according to the load, extending the fan’s service life and reducing noise.
09.
The static switch has an extremely short switching time, enabling seamless, disturbance-free switching.
Employing 32-bit DSP digital control technology and a current‑mode detection scheme, the switching time is reduced to 0.
10.
Data recording capability
All data and timestamps associated with abnormal conditions are stored in the UPS, enabling users to clearly monitor any issues that arise. Even during a power outage, the data retained in the UPS remains intact.
11.
Remote Diagnosis and Testing
Remote diagnostics and testing of multiple UPS systems are available via the Internet, ensuring your system operates with maximum reliability at all times.
12.
Intelligent Communication Interface
An RS‑232 port, four RS‑485 ports, and a standard communication protocol together form an intelligent monitoring system. It also supports SNMP devices for remote network management. More than 20 pairs of passive dry contacts are available for flexible configuration and use.
———— Product Principle Block Diagram ————


Block Diagram of the Industrial-Grade Three-Phase Input, Single-Phase Output SDP System


Principle Block Diagram of an Industrial-Grade Three-Phase Input/Three-Phase Output SDP System
———— Product Specification Sheet ————
| Model number | SDP | SDP | SDP | SDP | SDP | SDP | SDP | ||||
| 10 15 20 30 40 | 50 60 80 | 100 120 160 200 | 250~300 | 350~ 400 | 450~ 500 | 600~1080 | |||||
| UPS type | Double isolation, double conversion online type | ||||||||||
| Efficiency | >92% | ||||||||||
| UPS ambient temperature | -30~+50℃ (customizable within this temperature range to suit the environmental conditions of each country) | ||||||||||
| UPS storage temperature | -30~+70℃ | ||||||||||
| Relative humidity | <95% (non-condensing) | ||||||||||
| Height | <2000 m (above sea level) | ||||||||||
| Power derating at altitudes above 1500 m | 7%/km | ||||||||||
| Ventilation method | 1+1 redundant fans, forced air cooling, top-and-bottom airflow | ||||||||||
| Noise | <60dBA | <80dBA | |||||||||
| Input/Output Cable Connection | Bottom or top (optional) | ||||||||||
| Communication interface | RS232 (1 port) / RS485 (4 ports) / Dry contacts (1 set of 15 pairs), (SNMP optional) | ||||||||||
| Standardization | CE, EN 50091-1,2 | Compliant with | |||||||||
| FCC CLASS A | Compliant with | ||||||||||
| Protection circuit | Short-circuit protection | Rectifier/Backup Power Supply/Bypass Switch | |||||||||
| Lightning Protection | MOV | ||||||||||
| EMC protection | Input & Output | ||||||||||
| Quarantine | Full isolation of input, output, and bypass | ||||||||||
———— Rectifier Parameter Table ————
| Bridge rectifier | Three-phase 6-pulse controlled rectifier | Three-phase 12-pulse controlled rectifier | Three-phase 18-pulse controlled rectifier | Three-phase 24-pulse controlled rectifier | Three-phase 30-pulse controlled rectifier | Customizable for more than 36 pulses. | |||||
| Input isolation transformer | Standard configuration | ||||||||||
| Rated Input Voltage (VAC) | 3*190V/200V/208V/220V/230V/380V/400V/440V/460V/480V/500V/525V/600V/660V/690V | ||||||||||
| Input voltage range | -40%+35% | ||||||||||
| Input frequency | 50/60Hz±10% | ||||||||||
| Input power factor | >0.9 | >0.95 | >0.98 | ||||||||
| DC output voltage | 110VDC/216VDC/360VDC/384VDC | ||||||||||
| DC output voltage accuracy (with load varying from 0% to 100%) | 110VDC/216VDC/360VDC/384VDC±1% | ||||||||||
| Efficiency | 99% | ||||||||||
———— Inverter Parameter Table ————
| Bridge inverter | IGBT inverter with DSP control | ||||||||||
| Output isolation transformer | Standard configuration | ||||||||||
| DC input range | 110VDC/216VDC/360VDC/384VDC±25% | ||||||||||
| Rated output voltage | Single-phase: 110V/115V/120V/127V/130V/220V/230V/240V/254V/265V/277V/288V/300V/345V/380V/400V Three-phase (line voltage): 190V/200V/208V/220V/230V/380V/400V/415V/440V/460V/480V/500V/525V/600V/660V/690V |
||||||||||
| Number of output phases | Single-phase, three-phase | ||||||||||
| Output power factor | 0.8 | ||||||||||
| Output frequency | 50/60Hz±0.1% | ||||||||||
| Output voltage stability | Static | ±1% | |||||||||
| Dynamic (0~100%~0) |
±3% | ||||||||||
| Output voltage recovery time | After a step load, it recovers to within ±2% within 1 millisecond. | ||||||||||
| Overload capacity | 125% for 10 minutes, 150% for 1 minute. | ||||||||||
| Short-circuit characteristics | Short-circuit protection, current limiting at 3 times the rated current, 100 ms | ||||||||||
| Output waveform | Sine wave | ||||||||||
| Output waveform distortion | Linear load | <2% | |||||||||
| Nonlinear load (crest factor 3:1) | <5% | ||||||||||
| Peak factor | 3:1 (customizable to a crest factor greater than 3:1) | ||||||||||
| Efficiency | >93.5% | ||||||||||
| DC cold start | Can do. | ||||||||||
———— Bypass Parameter Table ————
| Automatic Static Switch | Thyristor SCR, (redundant design optional) | ||||||||||
| Rated voltage | 220V/230V/240V/380V/400V/415V ±20% (adjustable) | ||||||||||
| Rated frequency | 50/60 Hz ± 5% (adjustable) | ||||||||||
| Static bypass transfer time | 0ms | ||||||||||
| Inverter to Static Bypass | Inverter testing, inverter fault, excessive inverter input voltage, excessive inverter output voltage | ||||||||||
| Overload capacity | 1.5 | 30min | |||||||||
| 10 | 1min | ||||||||||
———— Mechanical Parameters Table ————
| Model number | SDP | SDP | SDP | SDP | SDP | SDP | SDP | SDP | SDP | ||
| 10 15 20 30 | 40 50 | 60 80 | 100 120 | 160 200 | 250~300 | 350~ 400 | 450~ 500 | 600~1080 | |||
| Protection rating | IP20, IP21, IP30, IP32, IP40, and IP42 are available; other options can be custom‑made. | ||||||||||
| W | 600 | 800 | 1200 | 1800 | 2400 | 3000 | 4800 | 6000 | Customizable | ||
| D | 800 | ||||||||||
| H1 | 1800 (IP20, IP30, IP40) | ||||||||||
| H2 | 2000(IP21, IP32, IP42) | ||||||||||
| Weight (kg) | 700~1000 | 1100-2000 | 2500-3000 | 3500-4000 | 4500-5000 | 5500-6000 | >6000 | ||||
Related products